Título: EVALUACIÓN DE UN POSTRATAMIENTO FISICOQUÍMICO PARA LA REMOCIÓN DE TURBIDEZ DE EFLUENTES DE UNA TENERÍA
EVALUATION OF A PHYSICOCHEMICAL POST-TREATMENT FOR REMOVAL OF TURBIDITY FROM TANNERY WASTEWATER
ISSN: 2343-6115
Fecha: 2016
Páginas/Colación: pp. 50-65
En:/ Agroindustria, Sociedad y Ambiente Vol 2 Nro 7 Julio- Diciembre 2016
Información de existenciaInformación de existencia
Categoría Temática: Palabras: AGR02 AGR02
Palabras Claves del Autor: Palabras: CLORURO FÉRRICO CLORURO FÉRRICO, Palabras: COAGULACIÓN-FLOCULACIÓN COAGULACIÓN-FLOCULACIÓN, Palabras: EFLUENTE DE TENERÍA EFLUENTE DE TENERÍA, Palabras: TURBIDEZ TURBIDEZ
Documentos asociados
Oprima aquí para visualizar el documento pdf:Documento en Formato PDF (423054 bytes) Documento en Formato PDF (423054 bytes)

RESUMEN
Se realizó un postratamiento fisicoquímico de coagulación-floculación a escala de laboratorio aplicando la prueba de jarra a efluentes de tenería provenientes de un tratamiento biológico. Se utilizaron coagulantes químicos (cloruro férrico) y coagulantes naturales (agua de mar) con una dosis fija 30 mL/L de floculante policloruro de aluminio marca Nalco (10 g/1000 mL). El objetivo fue evaluar el comportamiento de estos coagulantes probados individualmente en la eficiencia de remoción de turbidez. El postratamiento se ejecutó en dos etapas, de las cuales la primera correspondió al proceso de determinación del pH óptimo. El pH 11 permitió que los coagulantes actuaran de manera eficaz. Posteriormente, en la segunda etapa se determinó la dosis ideal de cada coagulante. La dosis óptima para el cloruro férrico fue de 10 mL/L, mientras que para el agua de mar la dosis ideal fue de 20 mL/L, en ambos casos removiendo porcentajes cercanos al 100% de turbidez. En esta segunda etapa ambos coagulantes lograron remover la turbidez a niveles no detectables Se concluye que la aplicación de un postratamiento fisicoquímico basado en el proceso de coagulación-floculación permitió generar un efluente cuya turbidez cumple con lo especificado en la normativa ambiental venezolana para un agua tipo 1, sub-tipo 1A.
Palabras clave: Turbidez, coagulación-floculación, cloruro férrico, agua de mar, efluente de tenería.

ABSTRACT
A physico-chemical post-treatment of coagulation-flocculation was carried out at laboratory scale, applying the jar test to tannery effluents from a biological treatment. Chemical coagulants (ferric chloride) and natural coagulants (seawater) were used with a fixed dose of 30 mL / L of Nalco brand polychloride aluminum flocculant (10 g / 1000 mL). The objective was to evaluate the behavior of these individually tested coagulants in turbidity removal efficiency. Posttreatment was performed in two stages, the first one corresponded to the selection of optimal pH. The pH 11 allowed the coagulants to act effectively. Subsequently, in the second stage, the ideal dose of each coagulant was determined. The optimal dose for ferric chloride was 10 mL / L, while for seawater the ideal dose was 20 mL / L, in both cases removing percentages close to 100% turbidity. In this second stage both coagulants were able to remove the turbidity to non-detectable levels. It was concluded that the application of a physico-chemical post-treatment based on the coagulation-flocculation process allowed the generation of an effluent whose turbidity complies with that specified in the Venezuelan environmental regulations for a type water 1, subtype 1A.
Key words: Turbidity, coagulation-flocculation, ferric chloride, seawater, tannery effluent.

REFERENCIAS BIBLIOGRAFICAS
- APHA, AWWA, WCF.(2005). Standard methods for examination of water and wastewater.
- Arboleda, J. ( 2000). Teoría y práctica de la purificación del agua. 3a. edición. Santa Fe de Bogotá. 163-180
- De Gisi, S., Galasso, M., De Feo, G. (2009). Treatment of tannery wastewater through the combination of a conventional activated sludge process and reverse osmosis with a plane membrane. Desalination, 249:337-342.
- Dosta, J., Rovira, J., Galí, A., Macé, S., Mata-Álvarez, J. (2008). Integration of a Coagulation/Flocculation step in a biological sequencing batch reactor for COD and nitrogen removal of supenantant of anaerobically digested piggery wastewater. Biosource Technology, 99 (13):5722-573.
- Durai, G.; Rajasimman, M. (2011). Biological Treatment of tannery wastewater - A review. Journal of Environmental Science and Tecnology, 4(1):1-17.
- Lofrano, G. Meric, S. Emel Zengin, G., Orthon, D. (2013). Chemical and biological treatment technologies for leather tannery chemicals and wastewaters: A review. Science of the total Enviroment 461-462: 265-281.
- MARN. Ministerio del Ambiente de Recursos Naturales Renovables y no Renovable. (1995). Ley ambiental venezolana. Decreto 883 de la Gaceta oficial 5.021. Extraordinario 18/12/1995. Sección III de las descargas a cuerpos de aguas Artículo 10.
- Nemerow, N. (1977). Aguas residuales industriales: teoría, aplicaciones y tratamiento. Españas.
- Oller, S. Malato, J.A. Sánchez-Pérez. (2011). Combination of advanced oxidation processes and biological treatments for wastewater decontamination - A review. Science of Total Environment 409:4141-4166.
- Pire-Sierra, M.C. (2012). Remoción de nutrientes en aguas residuales de una tenería aplicando tratamiento biológico y fisicoquímico. Tesis doctoral presentada en la Universidad del Zulia. Venezuela. 307 p.


 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

** Back-end Alejandría BE 7.3.0b3 *